Flame retardants division:

                        +86-13812233176(Manager Jiang)

                        +86-18156150062(Manager Sheng)

                        Blowing agent division:

                        +86-18156150062(Manager Sheng)


                        Surface activity division:

                        +86-18936052698(Manager Xu)

                        +86-17706153456(Manager Zhou)

                        Hot line:

                        +86-0561-7888202

                        +86-0510-87655898

                        ENGLISH

                        News

                        Your Current Location:Home - News - Enterprise news

                        News

                        News

                        Here you are concerned about the company dynamics and industry information

                        Enterprise environmental information disclosure report according to law

                        Release time:2022-04-30 11:10:58      Number of clicks:146

                        Enterprise environmental information disclosure report according to law

                        Company name: Anhui Runyue Technology Co., LTD

                        Unified Social credit code: 91340600MA2RNPW96J

                        Reporting year: 2021


                        Preparation date: January 8, 2022



                        Letter of commitment

                        In accordance with the Measures for the Management of Enterprise Environmental Information Disclosure according to Law (Order No. 24 of the Ministry of Ecology and Environment in 2021) and the Standards for the Format of Enterprise Environmental Information Disclosure according to Law (2022), our unit has prepared the 2021 Environmental Information Disclosure Report of Anhui Runyue Technology Co., LTD., which is true, accurate and complete. There are no false records, misleading statements or material omissions. Our unit will consciously accept the supervision of the competent department of environmental protection and the supervision of the public, if the content and data of the report are not consistent with the actual situation, we will actively cooperate with the investigation and accept punishment according to law.

                         
                         
                         

                        Company leader: Sheng Jiangfeng

                        Date: January 8, 2022



                        Letter of commitment

                        In accordance with the Measures for the Management of Enterprise Environmental Information Disclosure according to Law (Order No. 24 of the Ministry of Ecology and Environment in 2021) and the Standards for the Format of Enterprise Environmental Information Disclosure according to Law (2022), our unit has prepared the Environmental Information Disclosure Report of Shandong Qidu Pharmaceutical Co., Ltd. in 2021. The annual report is true, accurate and complete. There are no false records, misleading statements or material omissions. Our unit will consciously accept the supervision of the competent department of environmental protection and the supervision of the public. If the contents and data of the report are not consistent with the actual situation, we will actively cooperate with the investigation and accept punishment according to law.

                        Hereby promise.

                        Head of Environmental Protection: Miao Wenjing

                        Date: January 8, 2022
                         
                         

                        Section 1 Summary of key environmental information

                        In 2021, our company strictly abides by various ecological environment laws and regulations, has no environmental violations, and has not been punished by environmental protection departments at all levels. In terms of pollutant emission, the average concentration of C0D emission in 2021 will be 249mg/L, and the total emission will be 6.557t. The average ammonia emission concentration was 4.9mg /L, and the total emission was 0.1281t. The average emission concentration of nitrogen oxides was 5.79mg/m3, and the total emission was 1.53t. The average emission concentration of particulate matter is 1.06mg/m3, and the total emission is 0.281t. The average emission concentration of VOCs is 9.28mg/m3, and the total emission is 2.45t. In 2021, a total of 1488.6 tons of hazardous waste was generated, and 1503.8 tons of hazardous waste was entrusted to be disposed of. The hazardous waste disposal units were Suzhou Haichuang Environmental Protection Technology Co., LTD., and Anhui Donghuatongyuan Ecological Technology Co., LTD.

                        Section 2 Basic information of the enterprise

                        1. Basic information

                        Company name: Anhui Runyue Technology Co., LTD

                        Type of enterprise: Limited liability company (natural person investment or holding)

                        Legal representative: Sheng Jiangfeng

                        Registered address: No.1 New coal chemical synthetic Materials Base, Huaibei City, Anhui Province

                        Production address: No.1 new coal chemical synthetic material Base, Huaibei City, Anhui Province

                        Industry Category: Organic chemical raw material manufacturing

                        List of key pollutant discharge units Category: gas, soil

                        Cleaner production audit: No

                        Enterprise contact: Xu Zongwei 0561-7886086

                        2. Product information

                        The company's main products include blowing agent series and phosphorous flame retardant series products, the production process name is nitrosation reaction process, esterification reaction process, the production process belongs to the state, local and other announced encouraged processes.

                        Section 3 Enterprise environmental management information

                        Enterprises shall disclose the relevant information of all ecological environmental administrative permits (including but not limited to emission permits, environmental impact assessments of construction projects, hazardous waste business permits, waste electrical and electronic products disposal qualification permits, etc.) that are valid or are being applied for issuance or change:

                        First, ecological environment administrative license disclosure information

                        Table 1: List of ecological and environmental administrative license information in 2021


                        License name

                        Pollutant discharge permit

                        Annual production of 20,000 tons of foaming agent series products and 86,000 tons of phosphorus series flame retardant series products project environmental impact assessment

                        An annual output of 60,000 tons of large phosphate (2-chloropropyl) ester (TCPP) project environmental impact assessment

                        ID

                        91340600MA2RNPW96J00IP

                        Huai Ring Road [2018] No. 42

                        Huai Ring Road [2021] No. 02

                        Approval documents for obtaining permission

                        Pollutant discharge permit

                        Eia approval

                        Eia approval

                        Issuing authority

                        Huaibei City ecological environment Bureau

                        Huaibei City Environmental Protection Bureau

                        Huaibei City ecological environment Bureau

                        Acquisition time

                        2020.6.17

                        2018.11.7

                        2021.2.7

                        Validity period

                        2023.6.17

                        /

                        /

                        Major permit

                        Basic information of pollutant discharge units, air pollution discharge, water pollutant discharge, noise discharge information, solid waste discharge information, environmental management requirements, permit changes, continuation records, etc

                        /

                        /

                        remark

                        /

                        approved

                        approved

                         

                        Environmental protection tax payment disclosure information


                        In 2021, our company did not pay environmental protection tax.

                        Third, environmental pollution liability insurance insurance disclosure information

                        Our company is not insured against environmental pollution liability.

                        Fourth, the enterprise environmental protection credit evaluation level disclosure information

                        Our company did not participate in the 2020 annual environmental credit assessment.

                        Section 4 Information on pollutant generation, treatment and discharge

                        1. Disclosure of pollution control facilities

                        Table 2: Information list of the company's pollution control facilities


                         

                        Serial number

                        Name of pollution control facility

                        Corresponding pollution production link

                        Treated pollutant

                        Name of the sewage outlet

                        Sewage outlet

                        ID


                        1

                        Sewage treatment system

                        Process wastewater, spray tower wastewater, primary washing wastewater of production equipment, domestic sewage, initial rainwater

                        C0D, ammonia nitrogen, total phosphorus, total nitrogen, etc

                        Main waste water outlet

                        DW001

                        2

                        Organic waste gas treatment facilities

                        TCPP, TCEP, TEP workshop waste gas; Tank farm exhaust; Sewage treatment station, MVR evaporation salt, sodium sulfate temporary storage, hazardous waste gas storage

                        Odor concentration,

                        Ammonia, hydrogen sulfide

                        Volatile organic compounds, hydrogen chloride, ethylene oxide, propylene oxide, sulfuric acid fog, NMHC


                        Exhaust gas main outlet

                        DA001

                        3

                        Urea ester auxiliary production waste gas treatment facilities

                        Urea coester production waste gas, raw material feeding waste gas; Pulverizing and packaging process dust; MVR evaporates salt-out exhaust gas

                        Ammonia, odor concentration, particulate matter

                        Urea grease additive exhaust gas outlet

                        DA002

                        4

                        H workshop drying equipment waste gas treatment facilities

                        Drying plant exhaust gas

                        Particulate matter

                        H workshop drying device exhaust gas outlet

                        DA003

                        5

                        H workshop production of waste gas treatment facilities

                        H blowing agent unit nitrosation reaction waste gas; Nitrogen containing waste gas of washing tank, high tank and other devices; Pulverizing, screening, packaging equipment dust exhaust gas

                        Particulate matter, nitrogen oxide, ammonia, formaldehyde, odor concentration

                        H workshop production exhaust gas outlet

                        DA004

                        6

                        Tank farm hydrogen chloride waste gas treatment facilities

                        Tank farm hydrogen chloride gas

                        Hydrogen chloride

                        Tank farm hydrogen chloride exhaust outlet

                        DA005

                        Note: In 2021, all pollution prevention and control facilities of the company are in normal operation, and no third party is commissioned for operation and maintenance.

                        2. Disclosure of discharge of major water pollutants and air pollutants

                        (1) The number of discharge outlets for water pollutants and air pollutants; The actual total amount of various pollutants discharged at major sewage outlets, the annual average daily concentration of water pollutants, and the annual average hourly concentration of air pollutants; Installation of pollution source online automatic monitoring equipment at each sewage outlet and networking with ecological environment departments;

                        The water pollution discharge outlet of our company includes 1 total waste water discharge outlet and 1 rainwater discharge outlet, of which the total waste water discharge outlet is the main discharge outlet; There are a total of 5 air pollutant discharge ports, of which 1 main discharge port, the specific situation is as follows:

                        Table 3: Discharge of major sewage outlets in 2012


                        Serial number

                        Name of the main vent

                        Sewage outlet type

                        Pollutant name

                        Actual total emission(t)

                        Average daily concentration
                        mg/1) / Average hourly concentration
                        mg/m3)

                        Online device installation

                        Online device networking

                        1

                        Main waste water outlet

                        Exhaust gas

                        COD

                        6.557

                        249

                        Installed

                        Networked

                        Ammonia nitrogen

                        0.1281

                        4.9

                        Installed

                        Networked

                        Total phosphorus (P)

                        /

                        2.9

                        uninstalled

                        /

                        Total nitrogen (N)

                        /

                        11.9

                        uninstalled

                        /

                        Suspended matter

                        /

                        11.1

                        uninstalled

                        /

                        pH value

                        /

                        /

                        uninstalled

                        /

                        Total dissolved solids

                        /

                        281

                        uninstalled

                        /

                        Five-day BOD

                        /

                        11.0

                        uninstalled

                        /

                        2

                        Exhaust gas main outlet

                        Exhaust gas

                        Volatile organic compounds

                        2.45

                        9.28

                        Installed

                        Networked

                        Propylene oxide

                        /

                        /

                        uninstalled

                        /

                        Ammonia (ammonia gas)

                        /

                        0.86

                        uninstalled

                        /

                        Odor concentration

                        /

                        3.6

                        uninstalled

                        /

                        Ethylene oxide

                        /

                        /

                        uninstalled

                        /

                        Hydrogen chloride

                        /

                        0.06

                        uninstalled

                        /

                        Sulfuric acid fog

                        /

                        0.12

                        uninstalled

                        /

                        Hydrogen sulfide

                        /

                        0.26

                        uninstalled

                        /

                        Nitrogen oxide

                        /

                        5.79

                        uninstalled

                        /




                        Particulate matter

                        /

                        1.06

                        uninstalled

                        /

                        Discharges without organization;


                        Table 4: Overview of unorganized monitoring for 2021


                        Serial number

                        Sampling date

                        Monitoring item

                        Monitor the site, monitor the fruit(mg/m3)

                        upwind

                        Downwind 1

                        Downwind 2

                        Downwind 3

                        1

                        October 13th

                        Total non-methane hydrocarbons

                        0.72

                        0.82

                        1.01

                        0.86

                        VOCs

                        0.121

                        0.191

                        0.141

                        0.246

                        Sulfuric acid fog

                        0.011

                        0.008

                        0.012

                        0.009

                        Odor concentration

                        <10

                        <10

                        <10

                        <10

                        Hydrogen chloride

                        0.095

                        0.104

                        0.095

                        0.095

                        Hydrogen sulfide

                        <0.001

                        <0.001

                        <0.001

                        <0.001

                        ammonia

                        0.06

                        0.13

                        0.07

                        010

                        Total suspended particulate matter

                        0.167

                        0.285

                        0.234

                        0.234

                        2

                        The 18th of August

                        Total non-methane hydrocarbons

                        0.89

                        1.13

                        1.41

                        0.94

                        VOCs

                        0.797

                        0.902

                        0.856

                        0.717

                        Sulfuric acid fog

                        <0.005

                        <0.005

                        <0.005

                        <0.005

                        Odor concentration

                        <10

                        <10

                        <10

                        <10

                        Hydrogen chloride

                        0.114

                        0.104

                        0.111

                        0.125

                        Hydrogen sulfide

                        <0.001

                        <0.001

                        <0.001

                        <0.001

                        ammonia

                        0.10

                        0.20

                        0.13

                        0.31

                        Total suspended particulate matter

                        0.167

                        0.217

                        0.251

                        0.234

                        3

                        On May 26th

                        Total non-methane hydrocarbons

                        1.34

                        1.33

                        1.35

                        1.19

                        VOCs

                        0.016

                        0.056

                        0.092

                        0.073

                        Sulfuric acid fog

                        0.005

                        0.005

                        0.005

                        0.005

                        Odor concentration

                        <10

                        <10

                        <10

                        <10

                        Hydrogen chloride

                        0.078

                        0.096

                        0.081

                        0.102

                        Hydrogen sulfide

                        <0.001

                        <0.001

                        <0.001

                        <0.001

                        ammonia

                        0.04

                        0.08

                        0.06

                        0.09

                        Total suspended particulate matter

                        0.151

                        0.234

                        0.247

                        0.268

                        4

                        The 30th of March

                        Total non-methane hydrocarbons

                        0.63

                        0.72

                        0.93

                        0.81

                        Hydrogen chloride

                        ND

                        ND

                        0.023

                        ND

                        Sulfuric acid fog

                        ND

                        ND

                        0.006

                        0.005

                        Hydrogen sulfide

                        0.002

                        0.003

                        0.005

                        0.004

                        ammonia

                        0.08

                        0.11

                        0.14

                        0.09

                        Particulate matter

                        0.115

                        0.123

                        0.144

                        0.131

                         

                        (3) annual production days, self-monitoring days (number), number of standards, number of exceedance; Entrusted third-party inspection (supervision) testing institutions to conduct self-testing, shall provide the name of the third-party institution, qualification and other relevant information.

                        Table 5: Statistical table of self-monitoring in 2012


                        Days of annual production

                        Outlet name

                        pollutant

                        Self-monitoring days (times)

                        Number of attainment

                        Exceedance number

                        Third-party testing organization

                        name

                        aptitude

                        365

                        Effluent outlet

                        PH

                        12

                        12

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Suspended matter

                        12

                        12

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Total phosphorus

                        12

                        12

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Total nitrogen

                        12

                        12

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Five-day BOD

                        5

                        5

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Total dissolved solids

                        5

                        5

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        365

                        Plant organic exhaust gas outlet
                        DA001)

                        ammonia

                        5

                        5

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Hydrogen sulfide

                        10

                        10

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Total non-methane hydrocarbons

                        4

                        4

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Sulfuric acid fog

                        3

                        3

                        0

                        Anhui world standard testing Technology Co., LTD

                        171212050951

                        Hydrogen chloride

                        4

                        4

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        VOCS

                        4

                        4

                        0

                        Anhui world standard testing Technology Co., LTD

                        171212050951

                        Odor concentration

                        3

                        3

                        0

                        Anhui world standard testing Technology Co., LTD

                        171212050951


                        H blowing agent drying production exhaust gas discharge port
                        DA002)

                        Particulate matter

                        5

                        5

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202


                        Urea grease aid production workshop exhaust gas outlet
                        DA003)

                        Particulate matter

                        5

                        5

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        ammonia

                        1

                        1

                        0

                        安徽世標檢測技術有限公司

                        171212050951


                        H Blowing agent workshop is equipped with sub-digestion reaction exhaust gas discharge port
                        DA004)

                        Particulate matter

                        5

                        5

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Nitrogen oxide

                        5

                        5

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        ammonia

                        1

                        1

                        0

                        Anhui world standard testing Technology Co., LTD

                        171212050951

                        365

                        Tank farm HCL exhaust outlet
                        DA005)

                        Hydrogen chloride

                        4

                        4

                        0

                        Anhui world standard testing Technology Co., LTD

                        Anhui Bizhiyuan environmental testing Co., LTD


                        171212050951
                        181212051202

                        Industrial solid waste disclosure information

                        General industrial solid waste generation, storage, direction and use of disposal information

                        Table 6: - General industrial solid waste information list


                        name

                        output(t)

                        Disposal mode

                        Disposal volume(t)

                        Storage capacity(t)

                        Entrusted disposal unit

                        Entrusted disposition

                        Mode of transport

                        Temporary location

                        Domestic garbage

                        96.9

                        Entrusted disposal

                        96.7

                        0.2

                        Suixi County Huabang Property services Co., LTD

                        Comprehensive utilization

                        Automobile transport

                        Factory trash can

                        Hazardous waste generation, storage, direction and use of disposal information

                        Table 7: List of hazardous waste information


                        name

                        Junk code

                        Major harmful ingredient

                        Dangerous characteristic

                        Yield (t)

                        Temporary location

                        Floor area (m2)

                        Latitude and longitude coordinates

                        Entrusted disposition

                        sludge

                        900-409-06

                        Organic matter

                        Toxicity

                        623.025

                        Hazardous waste storage warehouse

                        50

                        116.571435
                        33.623031

                        Incineration, cement kiln disposal

                        Waste salt

                        900-409-06

                        Organic matter

                        Toxicity

                        846.455

                        Incineration, landfill, cement kiln disposal

                        Waste activated carbon

                        900-039-49

                        Nitrogen oxide

                        Toxicity

                        7.86

                        incineration

                        Circulating cooling water settling salt

                        900-046-49

                        Organic matter

                        Toxicity

                        0.48

                        incineration

                        Waste bag

                        900-041-49

                        Organic matter

                        ignitability

                        1.22

                        incineration

                        Waste demineralized water membrane

                        900-015-13

                        Organic matter

                        ignitability

                        0

                        incineration

                        name

                        Disposal mode

                        Disposal volume (t)

                        Storage capacity (t)

                        aptitude

                        Entrusted disposal unit

                        Is there a transfer order

                        Mode of transport

                        sludge

                        Entrusted disposal

                        629.38

                        1.7

                        340222002
                        341302005
                        340406002

                        Wuhu Haichuang, Suzhou Haichuang Environmental Protection Technology Co., LTD., Anhui Donghua Tongyuan Ecological Technology Co., LTD
                         

                        There are

                        Automobile transport

                        Waste salt

                        855.3

                        21.68

                        There are

                        Automobile transport

                        Waste activated carbon

                        7.86

                        0

                        340406002

                        Anhui Donghua Tongyuan ecological technology Co., LTD

                        There are

                        Automobile transport

                        Circulating cooling water settling salt

                        0.48

                        0

                        There are

                        Automobile transport

                        Waste bag

                        1.22

                        0

                        There are

                        Automobile transport

                        Waste demineralized water membrane

                        0

                        0

                        /

                        /

                        4. Disclosure of toxic and harmful substances discharge

                        According to the "List of Toxic and Harmful Air Pollutants", "List of Toxic and Harmful Water Pollutants" and "List of Priority Controlled Chemicals", it is determined that our company does not involve toxic and harmful substances in the atmosphere and water.


                        Noise emission information disclosure


                        Name of noise emission monitoring point: factory boundary

                        Location: East factory boundary, South factory boundary, West factory boundary, North factory boundary

                        Implementation standards: "Industrial Enterprise factory boundary environmental noise emission standards" (GB12348-2008) in the 3 standard limit requirements

                        Emission limit: ≤65dB(A) during the day, ≤55dB(A) at night

                        East Factory boundary: 54-61 day and 45-52 night

                        South factory boundary: 57-60 day and 45-53 night

                        West Factory boundary: 54-62 by day and 45-53 by night

                        North Factory boundary: 55-63 day and 45-52 night

                        6. Emission permit disclosure information

                        Our company is a key emission permit management enterprise, in 2021, we should prepare public emission permit implementation report 12 times a month, four times a quarterly report, one time an annual report, the actual preparation and disclosure of 17 times, and the relevant information is released on the national emission permit information management platform.

                        Section V Carbon emission information

                        Our company has not been included in the quota management of the carbon emission trading market.

                        Section VI Mandatory cleaner production audit information

                        Our company has not yet been included in the mandatory cleaner production audit.

                        Section 7 Emergency information of ecological environment

                        First, ecological and environmental emergency information disclosure

                        (1) Emergency plan for environmental emergencies

                        Case authorities: Huaibei City Environmental Emergency Center

                        Filing number: 340600-2021-042-H

                        (2) Existing ecological and environmental emergency resources

                        1. According to the laws and regulations on environmental protection and the actual production situation of the company, the company has prepared the "Emergency Plan for Environmental Emergencies" and elaborated on the emergency situations such as fire and explosion. The factory has set up an emergency rescue command group for environmental emergencies, which includes emergency rescue group, material support group, medical rescue group, emergency monitoring group, etc. Each team has a clear division of labor and is fully staffed, which can ensure the rapid handling of the company's risk accidents.

                        2, emergency supplies and emergency equipment


                         

                        Statistical table of emergency material reserves in 2021


                        Applicant: Anhui Runyue Technology Co., LTD                                  Submission date: April 30, 2021

                        Name of material

                        Ladder

                        Woven bag

                        Shovel

                        raincoat

                        Rain boots

                        Guard line

                        Rescue line

                        Strong light flashlight (explosion-proof)

                        Dewatering pump

                        sandbag

                        Oil absorbent felt

                        Quantity of materials

                        2

                        100

                        10

                        20

                        20

                        100meter

                        100meter

                        5

                        4channels

                        100

                        20slice

                        store

                        Hardware warehouse

                        Hardware warehouse

                        Hardware warehouse

                        workshop

                        workshop

                        Hardware warehouse

                        Hardware warehouse

                        workshop

                        Hardware warehouse

                        Zte field

                        Hardware warehouse

                        remark













                        (3) The occurrence and disposal of environmental emergencies.

                        In 2021, there were no environmental emergencies in our company.

                        Second, heavy pollution weather emergency response information disclosure

                        Table 10: Heavy pollution weather emergency response information list


                        Response period

                        Lv.

                        Performance grading and results

                        Measure requirement

                        Actual implementation of the measures

                        remark

                        January 4, 24:00

                        January 5th, 9:00

                        II level

                        B level

                        Stop using national IV and below heavy cargo vehicles (including gas) for transportation; The turnover and turnover frequency of the tank farm, the loading and unloading frequency of the loading and unloading area, and the filling volume and filling frequency of the tank farm all decreased to 80% of the pre-warning level

                        Stop using national IV and below heavy cargo vehicles (including gas) for transportation; The turnover and turnover frequency of the tank farm, the loading and unloading frequency of the loading and unloading area, and the filling volume and filling frequency of the tank farm all decreased to 80% of the pre-warning level

                        Livelihood immunity

                        January 20 at 00:00

                        January 28th, 20:00

                        II level

                        16 November 12:00

                        November 19, 24:00

                        II level

                        12:00 on 9 December

                        December 12th, 20:00

                        II level

                        December 14, 18:00

                        December 17th, 9:00

                        II level

                        21 December 18:00 to

                        December 24, 9:00

                        II level

                        12:00 on 15 January

                        12 o 'clock on January 16

                        Ⅲ level

                        B level

                        Stop the use of national IV and below heavy cargo vehicles (including gas) for transport

                        Stop the use of national IV and below heavy cargo vehicles (including gas) for transport


                        24 June, 12:00

                        June 25th at 11:00

                        Ⅲ level

                         

                        Section 8 Ecological environment illegal information

                        In 2021, our company has no ecological environment illegal information.

                        Section 9 Interim report of the current year

                        In 2021, our company did not issue an interim report.



                        Previous:Anhui Runyue Technology Co., Ltd. year facility completion date and commissioning time publicity
                        Next:Anhui Runyue Technology Co., Ltd. hazardous waste pollution prevention information disclosure

                        Return list

                        News you are interested in
                        COPYRIGHT ? 2023 ALL RIGHTS RESERVEDAnhui Runyue Technology Co., LTD
                        亚洲精品1卡2卡三卡23卡